The collector performance can be characterized by the following five variables that are available from PV array manufacturers: the open-circuit voltage, the short-circuit current, the voltage and current at the maximum power-point, and the temperature coefficient of the open-circuit voltage. These are described below.
Short-Circuit Current | |
---|---|
Applicability |
All PV systems |
Definition |
Isc - current measured with zero voltage |
Units |
Amps |
Input Restrictions |
From manufacturer's specification |
Baseline Building |
None (PV not modeled for the baseline building) |
Open-Circuit Voltage | |
---|---|
Applicability |
All PV systems |
Definition |
Voc - voltage measured with an open circuit |
Units |
Volts |
Input Restrictions |
From manufacturer's specification |
Baseline Building |
None (PV not modeled for the baseline building) |
Maximum Power-Point Voltage and Current | |
---|---|
Applicability |
All PV systems |
Definition |
Imp, Vmp - current and voltage at the maximum power-point condition. These parameters are typically reported at Standard Test Conditions of 1000 W/m2 and a cell temperature of 25°C. |
Units |
Amps and Volts |
Input Restrictions |
From manufacturer’s specification |
Baseline Building |
None (PV not modeled for the baseline building) |
Open-Circuit Temperature Coefficient | |
---|---|
Applicability |
All PV systems |
Definition |
Temperature coefficient of the open circuit voltage (Voc) measures the changing open circuit voltage values of the PV module when the temperature increases (or decreases) |
Units |
%/ºC |
Input Restrictions |
From manufacturer's specification |
Baseline Building |
None (PV not modeled for the baseline building) |
Short Circuit Temperature Coefficient | |
---|---|
Applicability |
All PV systems |
Definition |
Temperature coefficient of the short-circuit current (Isc) measures the changing short-circuit current values of the PV module when the solar cell temperature increases (or decreases) |
Units |
%/ºC |
Input Restrictions |
From manufacturer’s specification |
Baseline Building |
None (PV not modeled for the baseline building) |
Nominal Operating Cell Temperature (NOCT) | |
---|---|
Applicability |
All PV systems |
Definition |
The normal operating cell temperature, typically between 45°C and 55°C |
Units |
Degrees Celsius (°C) |
Input Restrictions |
From manufacturer’s specification |
Baseline Building |
None (PV not modeled for the baseline building) |
PV Array Mounting Type | |
---|---|
Applicability |
All PV systems |
Definition |
The array type describes whether the PV modules in the array are fixed, or whether they move to track the movement of the sun across the sky with one or two axes of rotation. |
Units |
List: Fixed, one axis tracking, two axis tracking |
Input Restrictions |
As designed. The default value is a fixed, or no tracking. |
Baseline Building |
None (PV not modeled for the baseline building) |
PV Array Mounting Type | |
---|---|
Applicability |
All PV systems |
Definition |
The array type describes whether the PV modules in the array are fixed, or whether they move to track the movement of the sun across the sky with one or two axes of rotation |
Units |
List: Fixed, one axis tracking, two axis tracking |
Input Restrictions |
As designed. The default value is a fixed, or no tracking. |
Baseline Building |
None (PV not modeled for the baseline building) |