3.2.6 Energy Price Data

Annual energy costs shall be determined using either actual tariffs of purchased energy or the state average energy prices published by the Energy Information Administration (EIA). COMNET also provides default time-of-use rates based on state averages. Rates from different sources cannot be mixed for the same project.

 

Currency

Applicability

All projects

Definition

The currency used to compare the proposed design and the baseline building. Cost is the currency used for most purposes, although the Design to Earn ENERGY STAR and ASHRAE Building EQ programs use source energy.

Units

List: local energy costs, default time-of-use energy costs, EPA source energy, or site energy.

Input Restrictions

Energy modelers should use local rates when they are known and available, otherwise,

Baseline Rules

Same as the proposed design

 

Electric Utility Tariff

Applicability

When Currency (see above) is "local energy costs"

Definition

The local utility rate for electricity delivered to the building. The utility rate data entered under this descriptor may include a variety of rate features, such as demand charges, time of day rates, service charges, and taxes.

Units

Data structure

Input Restrictions

None

Baseline Rules

The baseline building shall use the same utility rate as the proposed design.

 

Gas Utility Tariff

Applicability

When Currency (see above) is "local energy costs"

Definition

The utility rates for natural gas delivered to the building. The utility rate data entered under this descriptor may include seasonal variations, service charges, and taxes.

Units

Data structure

Input Restrictions

None

Baseline Rules

The baseline building shall use the same utility rate as the proposed design.

 

 

 

 

Other Utility Tariff

Applicability

When Currency (see above) is "local energy costs"

Definition

The utility rates for chilled water, steam or other energy sources delivered to the building. The utility rate data entered under this descriptor may include seasonal variations, service charges, taxes, and other factors.

Units

Data structure

Input Restrictions

None

Baseline Rules

The baseline building shall use the same utility rate as the proposed design.

Building EQ

Not applicable for Design to Earn Building EQ.

Energy Star

Not applicable for Design to Earn ENERGY STAR.