Skip to main content
Home

Standardizing energy modeling for buildings

Search

User account menu

  • Community
  • News
  • Contact
  • About
  • Log in

Main navigation

  • Get Started
  • Modeling Guidelines
    • 90.1-2016 BM, 90.1-2019, 90.1-2022
    • Design to Earn ENERGY STAR
    • Legacy Modeling Guidelines
    • Derivative Modeling Guidelines
    • Training Videos - General Modeling Procedures
    • Training Videos - Building Descriptors
  • Resources
    • Reference Appendices
      • Appendix B - Modeling Data
      • Appendix C - Schedules
      • Appendix D - Construction Materials
      • Appendix H - Equipment Curves
      • Technical Support Document on COMNET Plug Loads
    • Advanced Modeling Tips
    • Default Energy Tariffs
    • Presentations
  • Standard Reports
    • Standard Reports
    • The Case for Standard Output
    • XML Schema
    • Training Video
  • Software Accreditation
    • Accreditation Procedures
    • Spreadsheets: Standard 140 Tests
    • Spreadsheets: Baseline Building and Modeling Tests
    • Training Videos
  1. Home
  2. Modeling Guidelines
  3. 2.0 General Modeling Procedures and Requirements
  4. 2.7 HVAC Capacity Requirements and Sizing
  • 1.0 Overview
  • 2.0 General Modeling Procedures and Requirements
    • 2.1 Simulation General Requirements
    • 2.2 General Requirements for Data from the User
    • 2.3 Thermal Blocks, HVAC Zones, and Space Functions
    • 2.4 Modeling Requirements for Zones
    • 2.5 Unmet Load Hours
    • 2.6 Calculation Procedures
    • 2.7 HVAC Capacity Requirements and Sizing
      • 2.7.1 Specifying HVAC Capacities for the Proposed Design
      • 2.7.2 Sizing Equipment in the Baseline Building
      • 2.7.3 Proposed Design with No HVAC, Lighting, SWH System or Receptacle Loads
        • 2.7.3.1 No HVAC System Intended
        • 2.7.3.2 No Lighting System Designed
        • 2.7.3.3 No HVAC System Designed
        • 2.7.3.4 No SHW System Designed
        • 2.7.3.5 No Power Systems Designed
      • 2.7.4 Existing Systems
  • 3.0 Building Descriptors Reference
  • 4.0 Energy Price Data
  • 5.0 Reporting

2.7.3 Proposed Design with No HVAC, Lighting, SWH System or Receptacle Loads

90.1-2019

This section addresses:

  • No HVAC System Intended
  • No Lighting System Designed
  • No HVAC System Designed
  • No SWH System Designed
  • No Power Systems Designed
90.1-2022

This section addresses:

  • No HVAC System Intended
  • No Lighting System Designed
  • No HVAC System Designed
  • No SWH System Designed
  • No Power Systems Designed
  • 2.7.3.1 No HVAC System Intended
  • 2.7.3.2 No Lighting System Designed
  • 2.7.3.3 No HVAC System Designed
  • 2.7.3.4 No SHW System Designed
  • 2.7.3.5 No Power Systems Designed

Book traversal links for 2.7.3 Proposed Design with No HVAC, Lighting, SWH System or Receptacle Loads

  • ‹ 2.7.2 Sizing Equipment in the Baseline Building
  • Up
  • 2.7.3.1 No HVAC System Intended ›