Wall Name | |
Applicability | All walls, optional input |
---|---|
Definition | A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units | Text, unique |
Input Restrictions | None |
Baseline Rules | None |
Wall Type | |
Applicability | All wall surfaces, optional |
---|---|
Definition | One of four categories of above-grade wall assemblies used to determine minimum insulation requirements for walls. The four wall type categories are as follows: a) mass walls, b) metal building walls, c) metal framing walls, and d) wood framing and other walls. These wall types are defined in the baseline standards and the associated User's Manuals. The prescriptive criteria of the baseline standards depend on the wall type, but for green building ratings and tax deduction calculations, the PRM specifies that all baseline walls shall be “metal framed” so the input is not used for the purposes of this manual. |
Units | List: mass walls, metal building walls, metal framing walls, and wood framing and other walls |
Input Restrictions | This input is optional for the purposes covered by this manual. This input can often be derived from other inputs and may not need to be explicitly specified. |
Baseline Rules | All walls in the baseline building are modeled as “metal framed.” |
Wall Geometry | |
Applicability | All walls, required input |
---|---|
Definition | Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units | Data structure: surface |
Input Restrictions | There are no restrictions other than that the surfaces defined must agree with the building being modeled, as represented on the construction drawings or as-built drawings. |
Baseline Rules | Wall geometry in the baseline building is identical to the proposed design. |
Wall Construction | |
Applicability | All walls, required input |
---|---|
Definition | A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units | Dimensionless reference |
Input Restrictions | All wall surfaces must reference a construction assembly that meets the mandatory requirements of the appropriate baseline standard. |
Baseline Rules | Walls in the baseline building are all of the type “metal framed”. The insulation requirement is determined by the baseline standard and climate zone and is given in [bookref id="baseline-building-r-value-and-u-factor-criteria-for-walls"]. The baseline building construction shall be modeled as layers as defined in [bookref id="baseline-building-wall-construction-assemblies"]. |
[table title="Baseline Building R-value and U-factor Criteria for Walls" id="baseline-building-r-value-and-u-factor-criteria-for-walls"]
Applicable Standard | Space Category | Climate Zone | Standard Design | |
Minimum Insulation | Maximum Assembly | |||
90.1 - 2001 | Nonresidential | 1-4 | R-13 | U-0.124 |
5,6 | R-13 + R-3.8 c.i. | U-0.084 | ||
7,8 | R-13 + R-7.5 c.i. | U-0.064 | ||
Residential | 1,2 | R-13 | U-0.124 | |
3 | R-13 + R-3.8 c.i. | U-0.084 | ||
4- 7 | R-13 + R-7.5 c.i. | U-0.064 | ||
8 | R-13 + 10.0 c.i. | U-0.055 | ||
Semi-Heated | 1- 3 | NR | U-0.352 | |
4 - 8 | R-13 | U-0.124 | ||
90.1 - 2007 | Nonresidential | 1,2 | R-13 | U-0.124 |
3 | R-13 + R-3.8 c.i. | U-0.084 | ||
4-8 | R-13 + R-7.5 c.i. | U-0.064 | ||
Residential | 1 | R-13 | U-0.124 | |
2-6 | R-13 + R-7.5 c.i. | U-0.064 | ||
7 | R-13 +15.6 c.i. | U-0.042 | ||
8 | R-13 + R-18.8 c.i. | U-0.037 | ||
Semi-Heated | 1 | NR | U-0.352 | |
2-7 | R-13 | U-0.124 | ||
8 | R-13 + R-3.8 c.i. | U-0.084 |
[table title="Baseline Building Wall Construction Assemblies" id="baseline-building-wall-construction-assemblies"]
Construction | Layer | Thickness (inch) | Conductivity (Btu/h ft F) | Density (lb/ft²) | Specific Heat (Btu/lb F) | R-value (ft²·°F·h/ Btu) |
U-factor (Btu/ ft²·°F·h) |
Wall R-13 + R-18.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-18.8 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 18.8 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 26.85 | 0.037 | |||||
Wall R-13 + R-15.6 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-15.6 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 15.6 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 23.65 | 0.042 | |||||
Wall R-13 + R-10.0 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-10.0continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 10.0 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 18.05 | .055 | |||||
Wall R-13 + R-7.5 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-7.5 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 7.50 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 15.55 | 0.64 | |||||
Wall R-13 + R-3.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-3.8 continuous insulation | 0.912 | 0.0200 | 1.8 | 0.29 | 3.80 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 11.85 | 0.84 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 199.95 | 0.124 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Cavity/steel framing | 0.79 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 2.84 | 3.52 |
Exterior Wall Surface Properties | |
Applicability | All walls |
---|---|
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. The descriptor is a critical default structure input, applicable to all models. Critical defaults require documentation to change. Data structures are outlined in the reference data structures section of this chapter. |
Units | Data structure: exterior surface properties |
Input Restrictions | The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |
Baseline Rules | The baseline building shall use default values for emittance and reflectance. The roughness of the baseline building walls shall be identical to the proposed design. |
Wall Name | |
Applicability | All walls, optional input |
---|---|
Definition | A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units | Text, unique |
Input Restrictions | None |
Baseline Rules | None |
Wall Type | |
Applicability | All wall surfaces, optional |
---|---|
Definition | One of four categories of above-grade wall assemblies used to determine minimum insulation requirements for walls. The four wall type categories are as follows: a) mass walls, b) metal building walls, c) metal framing walls, and d) wood framing and other walls. These wall types are defined in the baseline standards and the associated User's Manuals. The prescriptive criteria of the baseline standards depend on the wall type, but for green building ratings and tax deduction calculations, the PRM specifies that all baseline walls shall be “metal framed” so the input is not used for the purposes of this manual. |
Units | List: mass walls, metal building walls, metal framing walls, and wood framing and other walls |
Input Restrictions | This input is optional for the purposes covered by this manual. This input can often be derived from other inputs and may not need to be explicitly specified. |
Baseline Rules | All walls in the baseline building are modeled as “metal framed.” |
Wall Geometry | |
Applicability | All walls, required input |
---|---|
Definition | Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units | Data structure: surface |
Input Restrictions | There are no restrictions other than that the surfaces defined must agree with the building being modeled, as represented on the construction drawings or as-built drawings. |
Baseline Rules | Wall geometry in the baseline building is identical to the proposed design. |
Wall Construction | |
Applicability | All walls, required input |
---|---|
Definition | A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units | Dimensionless reference |
Input Restrictions | All wall surfaces must reference a construction assembly that meets the mandatory requirements of the appropriate baseline standard. |
Baseline Rules | Walls in the baseline building are all of the type “metal framed”. The insulation requirement is determined by the baseline standard and climate zone and is given in [bookref id="baseline-building-r-value-and-u-factor-criteria-for-walls"]. The baseline building construction shall be modeled as layers as defined in [bookref id="baseline-building-wall-construction-assemblies"]. |
[table title="Baseline Building R-value and U-factor Criteria for Walls" id="baseline-building-r-value-and-u-factor-criteria-for-walls"]
Applicable Standard | Space Category | Climate Zone | Standard Design | |
Minimum Insulation | Maximum Assembly | |||
90.1 - 2007 | Nonresidential | 1,2 | R-13 | U-0.124 |
3 | R-13 + R-3.8 c.i. | U-0.084 | ||
4-8 | R-13 + R-7.5 c.i. | U-0.064 | ||
Residential | 1 | R-13 | U-0.124 | |
2-6 | R-13 + R-7.5 c.i. | U-0.064 | ||
7 | R-13 +15.6 c.i. | U-0.042 | ||
8 | R-13 + R-18.8 c.i. | U-0.037 | ||
Semi-Heated | 1 | NR | U-0.352 | |
2-7 | R-13 | U-0.124 | ||
8 | R-13 + R-3.8 c.i. | U-0.084 |
[table title="Baseline Building Wall Construction Assemblies" id="baseline-building-wall-construction-assemblies"]
Construction | Layer | Thickness (inch) | Conductivity (Btu/h ft F) | Density (lb/ft²) | Specific Heat (Btu/lb F) | R-value (ft²·°F·h/ Btu) |
U-factor (Btu/ ft²·°F·h) |
Wall R-13 + R-18.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-18.8 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 18.8 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 26.85 | 0.037 | |||||
Wall R-13 + R-15.6 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-15.6 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 15.6 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 23.65 | 0.042 | |||||
Wall R-13 + R-10.0 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-10.0continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 10.0 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 18.05 | .055 | |||||
Wall R-13 + R-7.5 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-7.5 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 7.50 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 15.55 | 0.64 | |||||
Wall R-13 + R-3.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-3.8 continuous insulation | 0.912 | 0.0200 | 1.8 | 0.29 | 3.80 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 11.85 | 0.84 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 199.95 | 0.124 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Cavity/steel framing | 0.79 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 2.84 | 3.52 |
Exterior Wall Surface Properties | |
Applicability | All walls |
---|---|
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. The descriptor is a critical default structure input, applicable to all models. Critical defaults require documentation to change. Data structures are outlined in the reference data structures section of this chapter. |
Units | Data structure: exterior surface properties |
Input Restrictions | The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |
Baseline Rules | The baseline building shall use default values for emittance and reflectance. The roughness of the baseline building walls shall be identical to the proposed design. |
Wall Name | |
Applicability | All walls, optional input |
---|---|
Definition | A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units | Text, unique |
Input Restrictions | None |
Baseline Rules | None |
Wall Type | |
Applicability | All wall surfaces, optional |
---|---|
Definition | One of four categories of above-grade wall assemblies used to determine minimum insulation requirements for walls. The four wall type categories are as follows: a) mass walls, b) metal building walls, c) metal framing walls, and d) wood framing and other walls. These wall types are defined in the baseline standards and the associated User's Manuals. The prescriptive criteria of the baseline standards depend on the wall type, but for green building ratings and tax deduction calculations, the PRM specifies that all baseline walls shall be “metal framed” so the input is not used for the purposes of this manual. |
Units | List: mass walls, metal building walls, metal framing walls, and wood framing and other walls |
Input Restrictions | This input is optional for the purposes covered by this manual. This input can often be derived from other inputs and may not need to be explicitly specified. |
Baseline Rules | All walls in the baseline building are modeled as “metal framed.” |
Wall Geometry | |
Applicability | All walls, required input |
---|---|
Definition | Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units | Data structure: surface |
Input Restrictions | There are no restrictions other than that the surfaces defined must agree with the building being modeled, as represented on the construction drawings or as-built drawings. |
Baseline Rules | Wall geometry in the baseline building is identical to the proposed design. |
Wall Construction | |
Applicability | All walls, required input |
---|---|
Definition | A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units | Dimensionless reference |
Input Restrictions | All wall surfaces must reference a construction assembly that meets the mandatory requirements of the appropriate baseline standard. |
Baseline Rules | Walls in the baseline building are all of the type “metal framed”. The insulation requirement is determined by the baseline standard and climate zone and is given in Table 6.5.4-1. The baseline building construction shall be modeled as layers as defined in Table 6.5.4-2. |
Table 6.5.4-1: Baseline Building R-value and U-factor Criteria for Walls
Applicable Standard | Space Category | Climate Zone | Standard Design | |
Minimum Insulation | Maximum Assembly | |||
90.1 - 2007 | Nonresidential | 1,2 | R-13 | U-0.124 |
3 | R-13 + R-3.8 c.i. | U-0.084 | ||
4-8 | R-13 + R-7.5 c.i. | U-0.064 | ||
Residential | 1 | R-13 | U-0.124 | |
2-6 | R-13 + R-7.5 c.i. | U-0.064 | ||
7 | R-13 +15.6 c.i. | U-0.042 | ||
8 | R-13 + R-18.8 c.i. | U-0.037 | ||
Semi-Heated | 1 | NR | U-0.352 | |
2-7 | R-13 | U-0.124 | ||
8 | R-13 + R-3.8 c.i. | U-0.084 |
Table 6.5.4-2: Baseline Building Wall Construction Assemblies
Construction | Layer | Thickness (inch) | Conductivity (Btu/h ft F) | Density (lb/ft²) | Specific Heat (Btu/lb F) | R-value (ft²·°F·h/ Btu) |
U-factor (Btu/ ft²·°F·h) |
Wall R-13 + R-18.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-18.8 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 18.8 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 26.85 | 0.037 | |||||
Wall R-13 + R-15.6 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-15.6 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 15.6 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 23.65 | 0.042 | |||||
Wall R-13 + R-10.0 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-10.0continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 10.0 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 18.05 | .055 | |||||
Wall R-13 + R-7.5 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-7.5 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 7.50 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 15.55 | 0.64 | |||||
Wall R-13 + R-3.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-3.8 continuous insulation | 0.912 | 0.0200 | 1.8 | 0.29 | 3.80 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 11.85 | 0.84 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 199.95 | 0.124 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Cavity/steel framing | 0.79 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 2.84 | 3.52 |
Exterior Wall Surface Properties | |
Applicability | All walls |
---|---|
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. The descriptor is a critical default structure input, applicable to all models. Critical defaults require documentation to change. Data structures are outlined in the reference data structures section of this chapter. |
Units | Data structure: exterior surface properties |
Input Restrictions | The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |
Baseline Rules | The baseline building shall use default values for emittance and reflectance. The roughness of the baseline building walls shall be identical to the proposed design. |
Wall Name |
|
---|---|
Applicability |
All walls, optional input |
Definition |
A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units |
Text, unique |
Input Restrictions |
None |
Baseline Rules |
None |
Wall Type |
|
---|---|
Applicability |
All wall surfaces, optional |
Definition |
One of four categories of above-grade wall assemblies: a) mass walls, b) metal building walls, c) metal framing walls, and d) wood framing and other walls. These wall types are defined in Standard 90.1-2013 and the associated User's Manuals. The prescriptive criteria of the baseline standards depend on the wall type, but for performance calculations, the PRM specifies that all baseline walls shall be “metal framed”. |
Units |
List: mass walls, metal building walls, metal framing walls, and wood framing and other walls |
Input Restrictions |
This input is optional for the purposes covered by this manual. This input can often be derived from other inputs and may not need to be explicitly specified. |
Baseline Rules |
All walls in the baseline building are modeled as “metal framed.” |
Wall Geometry |
|
---|---|
Applicability |
All walls, required input |
Definition |
Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units |
Data structure: surface |
Input Restrictions |
The geometry of walls should match the construction documents or as-built drawings as accurately as possible. Unusual curved surfaces may be approximated by a series of flat constructions. |
Baseline Rules |
Wall geometry in the baseline building is identical to the proposed design. |
Wall Construction |
|
---|---|
Applicability |
All walls, required input |
Definition |
A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units |
Dimensionless reference |
Input Restrictions |
All wall surfaces must reference a construction assembly that meets the mandatory requirements of Standard 90.1-2013. |
Baseline Rules |
Walls in the baseline building are all of the type “metal framed”. The insulation requirement is determined by the baseline standard and climate zone and is given in Table 3.5.4-1. The baseline building construction shall be modeled as layers as defined in Table 3.5.4-2. |
Table 3.5.4-1: Baseline Building R-value and U-factor Criteria for Walls
Climate Zone |
Nonresidential |
Residential |
Semi-Heated |
|||
Name |
U-factor |
Name |
U-factor |
Name |
U-factor |
|
1 |
R-13 |
0.124 |
R-13 |
0.124 |
NR |
0.352 |
2 |
||||||
3 |
R-13+R-7.5 ci |
0.064 |
R-13 |
0.124 |
||
4 |
R-13+R-3.8 ci |
0.084 |
||||
5 |
||||||
6 |
||||||
7 |
R-13+R-7.5 ci |
0.064 |
||||
8 |
R-13+R-10 ci |
0.055 |
Table 3.5.4-2: Baseline Building Wall Construction Assemblies
Name |
Layer |
Thickness (inch) |
Conductivity |
Density (lb/ft²) |
Specific Heat (Btu/lb F) |
R-value (ft²·°F·h/ |
U-factor (Btu/ |
R-13 + R-10.0 |
Air film |
0.17 |
|||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
||
R-10.0 continuous insulation |
1.800 |
0.0200 |
1.8 |
0.29 |
10.0 |
||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
R-13 insulation/steel framing |
6.00 |
||||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Interior air film |
0.68 |
||||||
Total for assembly |
18.05 |
.055 |
|||||
R-13 + |
Air film |
0.17 |
|||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
||
R-7.5 continuous insulation |
1.800 |
0.0200 |
1.8 |
0.29 |
7.50 |
||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
R-13 insulation/steel framing |
6.00 |
||||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Interior air film |
0.68 |
||||||
Total for assembly |
15.55 |
0.64 |
|||||
R-13 + |
Air film |
0.17 |
|||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
||
R-3.8 continuous insulation |
0.912 |
0.0200 |
1.8 |
0.29 |
3.80 |
||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
R-13 insulation/steel framing |
6.00 |
||||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Interior air film |
0.68 |
||||||
Total for assembly |
11.85 |
0.84 |
|||||
R-13 |
Air film |
0.17 |
|||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
R-13 insulation/steel framing |
6.00 |
||||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Interior air film |
0.68 |
||||||
Total for assembly |
199.95 |
0.124 |
|||||
NR |
Air film |
0.17 |
|||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Cavity/steel framing |
0.79 |
||||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
||
Interior air film |
0.68 |
||||||
Total for assembly |
2.84 |
3.52 |
Exterior Wall Surface Properties |
|
---|---|
Applicability |
All walls |
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. Data structures are outlined in the reference data structures section of this chapter. |
Units |
Data structure: exterior surface properties |
Input Restrictions |
The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |
Baseline Rules |
The baseline building shall use default values for emittance and reflectance. The roughness of the baseline building walls shall be identical to the proposed design. |
Exterior Wall Name |
|
Applicability |
All walls, optional input |
Definition |
A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units |
|
Input Restrictions |
None |
Baseline Building |
None |
Wall Type |
|
Applicability |
All wall surfaces, optional |
Definition |
One of four categories of above-grade wall assemblies used to determine minimum insulation requirements for walls. The four wall type categories are as follows:
A mass wall is defined as a wall with total heat capacity greater than (1) 7 Btu/ft2·°F or (2) 5 Btu/ft2·°F, provided that the wall has a material unit weight not greater than 120 lb/ft3. (Heat capacity is defined as the product of the specific heat in Btu/lb -F, the thickness in ft, and the density in lb/ ft3.) Opaque spandrel panels are considered opaque wall and not fenestration. Standard 90.1-2019 defines fenestration as an assembly in the building envelope which allows light to pass. Hence an opaque spandrel wall is considered an experior wall and not fenestration. |
Units |
|
Input Restrictions |
As designed |
Baseline Building |
All walls in the baseline building are modeled as “steel framed” |
Wall Geometry |
|
Applicability |
All walls, required input |
Definition |
Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The geometry of roofs should match the construction documents or as-built drawings as accurately as possible. Curved surfaces such as a dome or semi-circular wall may be approximated by a series of constructions. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in Section 3.11.3 of this manual. |
Units |
|
Input Restrictions |
As designed |
Baseline Building |
Wall geometry in the baseline building is identical to the proposed design |
Wall Solar Reflectance |
|
Applicability |
All opaque exterior surfaces exposed to ambient conditions |
Definition |
The solar reflectance of a material |
Units |
|
Input Restrictions |
For walls and other non-roof surfaces, the default reflectance is 0.3. The default values may be overridden only when the lower reflectance can be documented by manufacturers’ literature or tests. |
Baseline Building |
Same as proposed |
Wall Thermal Emittance |
|
Applicability |
All opaque exterior surfaces exposed to ambient conditions; this is prescribed for exterior walls at 0.9 |
Definition |
The thermal emittance of a material. For roofing materials, the 3-year-aged emittance value from CRRC testing should be used if available. |
Units |
|
Input Restrictions |
For walls and other non-roof surfaces: The value is prescribed to be 0.9. The default values may be overridden only in cases when the lower emittance can be documented by manufacturers’ literature or tests. |
Baseline Building |
Same as proposed |
Wall Construction |
|
Applicability |
All walls that use the layers method |
Definition |
A specification containing a series of layers that result in a construction assembly for the proposed design. The first layer in the series represents the outside (or exterior) layer and the last layer represents the inside (or interior) layer. See the building descriptors above for wall construction type. Several software tools add the interior and exterior air films automatically to an envelope assembly. The interior and exterior air films should not be included in the construction in such cases. |
Units |
|
Input Restrictions |
As designed, with the construction assembly defined by a series of layers. Each layer specified, must consist of materials as described in Section 3.5.2. |
Baseline Building |
The baseline building wall type is steel framed where the insulation is installed within the cavity of the steel stud framing. The baseline building wall construction shall be modeled as layers. The U-factor required for baseline wall construction is defined in Table 23. The layer by layer construction corresponding to each U-factor shall be modeled as shown in Table 24. For existing buildings, the baseline walls shall follow the same rules as new buildings. |
Table 23. Standard 90.1-2019 Requirements for Baseline Wall Construction for Non-Residential Space Conditioning Categories
|
U-Factor (Btu/ft2. °F. h) |
||
Nonresidential |
Residential |
Semiheated |
|
Climate Zone 0 and 1 |
0.124 |
0.124 |
0.352 |
Climate Zone 2 |
0.124 |
0.084 |
0.352 |
Climate Zone 3 |
0.124 |
0.084 |
0.352 |
Climate Zone 4 |
0.124 |
0.064 |
0.124 |
Climate Zone 5 |
0.084 |
0.064 |
0.124 |
Climate Zone 6 |
0.084 |
0.064 |
0.124 |
Climate Zone 7 |
0.064 |
0.064 |
0.124 |
Climate Zone 8 |
0.064 |
0.055 |
0.124 |
Table 24. Baseline Building Wall Construction Assemblies
Construction |
Layer |
Thickness (inch) |
Conductivity (Btu/h ft °F) |
Density (lb/ft²) |
Specific Heat (Btu/lb °F) |
R-value (ft²·°F·h/ |
U-factor (Btu/ft2. °F. h) |
Wall R-13 + R-15.6 |
Air film |
0.17 |
|
||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
|
|
R-15.6 continuous insulation |
1.800 |
0.0200 |
1.8 |
0.29 |
15.6 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
R-13 insulation/steel framing |
6.00 |
|
|||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Interior air film |
0.68 |
|
|||||
Total for assembly |
23.65 |
0.055 |
|||||
Wall R-13 + R-7.5 |
Air film |
0.17 |
|
||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
|
|
R-7.5 continuous insulation |
1.800 |
0.0200 |
1.8 |
0.29 |
7.50 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
R-13 insulation/steel framing |
6.00 |
|
|||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Interior air film |
0.68 |
|
|||||
Total for assembly |
15.55 |
0.064 |
|||||
Wall R-13 + R-3.8 |
Air film |
0.17 |
|
||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
|
|
R-3.8 continuous insulation |
0.912 |
0.0200 |
1.8 |
0.29 |
3.80 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
R-13 insulation/steel framing |
6.00 |
|
|||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Interior air film |
0.68 |
|
|||||
Total for assembly |
11.85 |
0.084 |
|||||
Wall R-13 |
Air film |
|
|
|
|
0.17 |
|
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
|
|
|
|
|
6.00 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Interior air film |
|
|
|
|
0.68 |
0.124 |
|
Total for assembly |
|
|
|
|
8.05 |
|
|
NR |
Air film |
0.17 |
|
||||
Stucco |
0.400 |
0.4167 |
116 |
0.2 |
0.08 |
|
|
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Cavity/steel framing |
0.79 |
|
|||||
Gypsum board |
0.625 |
0.0930 |
50 |
0.2 |
0.56 |
|
|
Interior air film |
0.68 |
|
|||||
Total for assembly |
2.84 |
0.352 |
Existing walls shall follow the same requirement as defined for baseline buildings.
Wall Name | |
Applicability | All walls, optional input |
---|---|
Definition | A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units | Text, unique |
Input Restrictions | None |
Wall Geometry | |
Applicability | All walls, required input |
---|---|
Definition | Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units | Data structure: surface |
Input Restrictions | There are no restrictions other than that the surfaces defined must agree with the building being modeled, as represented on the construction drawings or as-built drawings. |
Wall Construction | |
Applicability | All walls, required input |
---|---|
Definition | A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units | Dimensionless reference |
Input Restrictions | All wall surfaces must reference a construction assembly that meets the mandatory requirements of the appropriate baseline standard. |
[table title="Baseline Building Wall Construction Assemblies" id="baseline-building-wall-construction-assemblies"]
Construction | Layer | Thickness (inch) | Conductivity (Btu/h ft F) | Density (lb/ft²) | Specific Heat (Btu/lb F) | R-value (ft²·°F·h/ Btu) |
U-factor (Btu/ ft²·°F·h) |
Wall R-13 + R-18.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-18.8 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 18.8 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 26.85 | 0.037 | |||||
Wall R-13 + R-15.6 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-15.6 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 15.6 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 23.65 | 0.042 | |||||
Wall R-13 + R-10.0 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-10.0continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 10.0 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 18.05 | .055 | |||||
Wall R-13 + R-7.5 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-7.5 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 7.50 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 15.55 | 0.64 | |||||
Wall R-13 + R-3.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-3.8 continuous insulation | 0.912 | 0.0200 | 1.8 | 0.29 | 3.80 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 11.85 | 0.84 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 199.95 | 0.124 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Cavity/steel framing | 0.79 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 2.84 | 3.52 |
Exterior Wall Surface Properties | |
Applicability | All walls |
---|---|
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. The descriptor is a critical default structure input, applicable to all models. Critical defaults require documentation to change. Data structures are outlined in the reference data structures section of this chapter. |
Units | Data structure: exterior surface properties |
Input Restrictions | The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |
Wall Name | |
Applicability | All walls, optional input |
---|---|
Definition | A unique name or code that relates the exterior wall to the design documents. This is an optional input since there are other acceptable ways to key surfaces to the construction documents. |
Units | Text, unique |
Input Restrictions | None |
Wall Geometry | |
Applicability | All walls, required input |
---|---|
Definition | Wall geometry defines the position, orientation, azimuth, and tilt of the wall surface. The details of how the coordinate system is implemented may vary between simulation engines. The data structure for surfaces is described in the reference section of this chapter. |
Units | Data structure: surface |
Input Restrictions | There are no restrictions other than that the surfaces defined must agree with the building being modeled, as represented on the construction drawings or as-built drawings. |
Wall Construction | |
Applicability | All walls, required input |
---|---|
Definition | A reference to a construction assembly for the proposed design. See the building descriptors above for construction assemblies. |
Units | Dimensionless reference |
Input Restrictions | All wall surfaces must reference a construction assembly that meets the mandatory requirements of the appropriate baseline standard. |
[table title="Baseline Building Wall Construction Assemblies" id="baseline-building-wall-construction-assemblies"]
Construction | Layer | Thickness (inch) | Conductivity (Btu/h ft F) | Density (lb/ft²) | Specific Heat (Btu/lb F) | R-value (ft²·°F·h/ Btu) |
U-factor (Btu/ ft²·°F·h) |
Wall R-13 + R-18.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-18.8 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 18.8 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 26.85 | 0.037 | |||||
Wall R-13 + R-15.6 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-15.6 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 15.6 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 23.65 | 0.042 | |||||
Wall R-13 + R-10.0 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-10.0continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 10.0 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 18.05 | .055 | |||||
Wall R-13 + R-7.5 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-7.5 continuous insulation | 1.800 | 0.0200 | 1.8 | 0.29 | 7.50 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 15.55 | 0.64 | |||||
Wall R-13 + R-3.8 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
R-3.8 continuous insulation | 0.912 | 0.0200 | 1.8 | 0.29 | 3.80 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 11.85 | 0.84 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
R-13 insulation/steel framing | 6.00 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 199.95 | 0.124 | |||||
Wall R-13 | Air film | 0.17 | |||||
Stucco | 0.400 | 0.4167 | 116 | 0.2 | 0.08 | ||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Cavity/steel framing | 0.79 | ||||||
Gypsum board | 0.625 | 0.0930 | 50 | 0.2 | 0.56 | ||
Interior air film | 0.68 | ||||||
Total for assembly | 2.84 | 3.52 |
Exterior Wall Surface Properties | |
Applicability | All walls |
---|---|
Definition |
The exterior wall surface properties descriptor describes the characteristics of exterior wall surfaces. Exterior surface properties may include emissivity, reflectivity and roughness. The first two govern radiation exchange from the surface, while the latter governs the magnitude of the exterior air film resistance. The descriptor is a critical default structure input, applicable to all models. Critical defaults require documentation to change. Data structures are outlined in the reference data structures section of this chapter. |
Units | Data structure: exterior surface properties |
Input Restrictions | The default value for emittance is 0.90. The default value for reflectance is 0.30. There is no default for roughness. The default values may be overridden only in cases when the lower reflectance can be documented by manufacturers’ literature or tests. |